Stack Members

The Stack Members tab displays the list of Instant On 1960 Series switches that are connected in the stack. The following details are displayed:

Table 1: Stack Details

Category

Description

Device

Displays the name of the Instant On device set by the administrator.

Health

Displays the health status of the Instant On devices connected at the site:

  • Good — Indicates that the health score is good.
  • Fair — Indicates the health score is fair.
  • Poor — Indicates the health score is poor.

State

Denotes the state of the Instant On device, such as Online, Offline, Restarting, Updating, or Synchronizing.

State Duration

Denotes the amount of time the device has been connected to the current state.

Type

Denotes the type of Instant On device - AP, switch, or stack.

Model

Displays the model type of the Instant On device.

MAC Address

Displays the MAC address of the Instant On device.

IP Address

Displays the IP address currently used by the Instant On device.

Role

Denotes the role assigned to the Instant On 1960 switch in the stack.

  • Conductor—The Conductor is the Instant On 1960 Series switch on which the stack is created.
  • Backup—Denotes the secondary Instant On 1960 Series switch which is configured in the stack. The Backup switch takes over the operations when the Conductor switch is offline.
  • Member—Denotes the third or fourth Instant On 1960 Series switch which is part of the stack.

Clients

Denotes the number of clients connected to the Instant On device.

Identification

The Stack Members > Identification section provides the basic details of the selected switch, which includes the switch name, status, and health. For more information, see Identification.

Connectivity

The Stack Members > Connectivity section allows you to configure the IP assignment for the Instant On switch. For more information, see Switch Details.

Hardware

The Stack Members > Hardware section displays the details pertaining to the switch hardware connected as a member in the stack. For more information, see Switch Details.

Power over Ethernet

The Stack Members > Power over Ethernet section displays the local network IP of the Instant On 1960 Series switches in the stack.

The Power over Ethernet section provides the following information:

  • Total budget—The total power in watts that can be provided by the Instant On 1960 Series switch. This information is displayed individually for each PoE switch in the stack.
  • Power consumption—The amount of power in watts currently being consumed by the connected PoE switches.

The Power over Ethernet section will not be displayed for non-PoE switches.

Restart Member

To restart a member of the switch stack, follow these steps:

  1. Under Stack Members, follow one of these steps:
    1. Clicking on the switch name of the standalone Instant On 1960 Series switch on which the member should be restarted.
    2. Hover the cursor to the end of the row of the standalone 1960 switch device, click the button, and select Restart from the drop-down list. You can also select View Details and click Restart next to the Restart Member.
  2. Click Restart Member in the popup window that appears on the screen.

Unstack Member

The following procedure is used to remove a member switch from the stack:

  1. Under Stack Members, follow one of these steps:
    1. Clicking on the switch name of the Instant On 1960 Series member switch.
    2. Hover the cursor to the end of the row of the 1960 switch stack member, click the button, and select Unstack from the drop-down list. You can also select View Details and click Unstack next to the Unstack.

    This option is available only if there are member switches in the stack. You can only remove member switches from the stack. The switches assigned to the Conductor and Backup roles cannot be removed.

  2. Click Unstack from the Unstack Member popup window.

    Removing a switch from the stack does not remove the device from the site, the switch will be listed on the site as a standalone switch.

    An Instant On 1960 series switch cannot be removed from the stack as long as it is assigned the role of a conductor or backup. To remove the switch, you must first swap the role of the conductor with a member and then remove the switch from the stack.

Change Roles

The Change Roles button provides an option to change the roles assigned to each Instant On 1960 Series switch in the stack.

Follow these steps to change the role of the switches in the stack:

  1. In the Stack Members screen, click the Change Roles button.
  2. Select a switch from each of the following dropdown lists to set the role:
    1. Conductor
    2. Backup
    3. Member
  3. Click Change Roles.

Conditions

The Conditions page displays the health conditions detected on the selected access point over the last 24 hours. Only the conditions of that access point are listed.

The chart displays the number of conditions detected during each interval of the last 24 hours, ending at Now. Hover over a bar to view the conditions detected during that interval.

The Conditions table displays the following information:

Table 2: Condition Details

Column Label

Description

Condition

Name of the condition. Click the condition name to open the side panel, which lists the symptoms, probable causes, and recommended actions for the condition.

Source Type

Type of source for which the condition is raised.

Source

Name of the source for which the condition is raised.

Severity

Severity of the condition.

When no condition is detected, the page displays No Conditions with the message No conditions detected.

Conditions listed on the Health > Overview page with a Source Type of Network link to the Conditions page of the corresponding network. For more information, see Monitoring Site Health.