Overview

The Overview tab of the Stack Details page consists of the following sections:

Identification

The Identification section provides the basic details of the selected switch stack, which includes the switch stack name, status, and health. To view the details of the switch, follow these steps:

  1. Click the Devices () tile on the Instant On web application home page or click Devices from the navigation pane on the left. The Device Overview page is displayed.
  2. Use one of the following methods to view the switch stack details:
    1. Clicking on the stack name.
    2. Hover the cursor to the end of the row of the switch stack, click the button, and select View Details from the dropdown list.

    The Overview > Identification section displays the following details:

    • Name—Denotes the device name specified by the administrator or the Serial Number of the device. The maximum number of characters supported is 32.

      To reset the switch stack name to its default name, click the reset icon and then click Update to save the change. The reset icon is displayed only when a custom device name is assigned.

    • Health—Displays the health status of the stack:
      • Good—Indicates that the health of the stack is good.
      • Fair—Indicates the health of the stack is fair.
      • Poor—Indicates the health of the stack is poor.
    • State—Denotes if the device is Online, Offline, Synchronizing, Rebooting, and Updating.
    • Online Since—Denotes the time duration for which the device has been online.
  3. The Locator Light setting is used to locate your device when there are many devices in the site. Slide the Locator Light toggle switch to right () to turn on the locator light in the all the devices in the stack. The locator light will be active for 30 minutes after you turn on the toggle switch. The light is turned off by default.
  4. To view the device in the topology view, click the View in topology link.

802.1X Authentication

Allows you to select the RADIUS profile for the device.

In the RADIUS Profile drop-down list, select either none, an existing RADIUS profile, or create a new RADIUS profile. For more information on creating a radius profile, see Creating a RADIUS Profile.

On assigning a RADIUS profile, View RADIUS Profile is displayed. Click View RADIUS Profile, opens the RADIUS profile detail panel on the right.

Click View Details, to view and edit an existing RADIUS profile.

Uplink

The uplink section displays the following information:

  • Device— The name of the uplink device. You can click on the link to view the device details page.
  • Uplink Device IP Address—The IP address of the uplink device.

Restart Stack

To restart the stack, follow these steps:

  1. Under Overview > Restart Stack, click the Restart button.
  2. Click Restart Stack in the popup window.

Unstack

Follow these steps to unstack the Instant On 1960 Series switches:

  1. Under Overview > Unstack, click Unstack. A popup appears on the screen requiring confirmation.
  2. Click Unstack.

    The stack is removed and the switches will now appear as standalone devices in the device inventory.

Advanced Options

The following selections are available under advanced options:

  • Allow Routing Between Networks
  • Allow Jumbo Frames

Routing

Configure routing on the Instant On switch. Routing is disabled by default. This feature is currently available only for Instant On 1930 Series and 1960 Series switches. To configure routing for the switch perform the following steps:

  1. Click the Devices () tile on the Instant On web application home page or click Devices from the navigation pane on the left. The Device Overview page is displayed.
  2. Use one of the following methods to view the switch details:
    1. Clicking on the switch name.
    2. Hover the cursor to the end of the row, click the button, and select View Details from the dropdown list.
  3. To enable routing on a switch or stack, under Overview > Device Options > Advanced Options, select the Allow routing between networks checkbox. To disable routing, deselect the checkbox.
  4. When Allow routing between networks is selected, icon is displayed in the device details page under Routes, next to networks that can be routed. If the icon is not visible, it implies that routing is turned off for the network. Hover the cursor to the end of row, click the button, and select Enable Routing.
  5. To configure routing for a network, under Routes, hover the cursor to the end of the row, click the button, and select Change IP addressing from the drop-down list:
    1. Configure either of the following options to assign an IP for the network:
      • Automatic (default) — The network will receive IP address from a DHCP server.
      • Static — Define the IP address assignment for the network by entering the following network parameters:
        • Network IP address — Enter the IP address for the network.
        • Subnet mask — Select a subnet mask from the drop-down list.
    2. Click the Change IP addressing to apply configuration changes. The routing configuration is applied after the Instant On switch reboots.
    • A minimum of two wired networks must be configured in the site to perform routing.
    • The Instant On switch must be online to configure routing.
    • Routing can be performed by only one Instant On switch in a site.
    • For a 1960 Series stack, the routing is defined at the stack level. If the conductor switch goes offline, then the backup switch takes over the routing service for the stack.

Jumbo Frames

Jumbo frames improve data transmission efficiency by reducing the number of frames and overheads for switches to process. Configuring jumbo frames is supported on all Instant On switches and can be enabled on each switch individually.

The following procedure allows you to configure jumbo frames on an Instant On switch:

  1. Under Overview > Advanced Options, select the Allow Jumbo frames checkbox.
  2. Click Update.

    The Instant On switch reboots automatically to apply the changes.

Once the setting is enabled on a 1960 Series switch stack, the configuration is applied to every Instant On switch in the stack. A new switch added to the stack will automatically adopt the jumbo frames configuration from the stack.

Reserving an IP Address for a Device

In addition to reserving an IP address from the network’s IP Assignment tab, you can also reserve or remove a device IP address directly from the device's page for both online and offline devices.

Follow these steps to reserve reserving an IP address from the device list:

  1. Click the Devices () tile on the Instant On web application home page or click , or click Inventory from the navigation pane on the left.
  2. Hover the cursor to the end of the row, click the button, and select Add IP Address Reservation. To remove it, select Remove IP Address Reservation.

Follow these steps to reserve reserving an IP address from the device details:

  1. Select the device from the list.
  2. Under Add IP Address Reservation, click Add.
  3. To remove the device IP address directly from the details, select Remove.

IP Reservation is only supported when Instant On functions as the DHCP server on the network, which occurs only when a Secure Gateway configured as a Wi‑Fi Router is present at the site.

Conditions

The Conditions page displays the health conditions detected on the selected access point over the last 24 hours. Only the conditions of that access point are listed.

The chart displays the number of conditions detected during each interval of the last 24 hours, ending at Now. Hover over a bar to view the conditions detected during that interval.

The Conditions table displays the following information:

Table 1: Condition Details

Column Label

Description

Condition

Name of the condition. Click the condition name to open the side panel, which lists the symptoms, probable causes, and recommended actions for the condition.

Source Type

Type of source for which the condition is raised.

Source

Name of the source for which the condition is raised.

Severity

Severity of the condition.

When no condition is detected, the page displays No Conditions with the message No conditions detected.

Conditions listed on the Health > Overview page with a Source Type of Network link to the Conditions page of the corresponding network. For more information, see Monitoring Site Health.