The Alert () icon appears on the title bar of the mobile app when there is a pending alert. The number of alerts in the system is displayed as a colored badge on top of the Alert () icon. The color of the badge determines the severity of the alert present in the system. When there are no alerts present in the system or all the alerts have been acknowledged, the Alert () icon will not appear in any of the title bars on the mobile app.

When there are multiple active alerts received by the application, the summary box in the Site Health page displays the active alerts with the highest severity in the system along with their color codes. For example: Major active alert takes the highest priority and is displayed in a red summary box. The Alerts page displays the list of active alerts in descending order of their severity and the order by which they should be acknowledged.

The table below shows the list of possible alerts:

Table 1: List of Alerts

Name

Severity

Description

Software available

Informational

A new software has been released

Site offline

Major

When all devices are offline

Device offline

Minor

Minor at first, becomes major after 5 minutes

Device underpowered

Major

When an AP does not receive enough power

Device not updated

Minor

Device failed the software update after repeated attempts.

Check that the device is connected. Check the configuration of network services (such as DHCP, DNS, and firewalls). Make sure the instant-on.hpe.com domain is allow-listed. Restart the device or Internet gateway. Review the software update status and try to reinstall the software version(click View software update/ Retry software update to open the Software page).

Domain offline

Major

All connections to the domain are down (main site)

Domain connection offline

Minor

The connection to the domain is down (connected site). Minor at first, becomes major after 5 minutes

Stack member offline

Minor

Minor at first, becomes major after 5 minutes

Stack members offline

Minor

Minor at first, becomes major after 5 minutes

Stack offline

Minor

Minor at first, becomes major after 5 minutes

Miswired stack

Major

Recabling does not allow the stack to function properly

Stack topology changed

Informational

Recabling change the type of stack topology (ring vs daisy chain)

Device power unit failure

Major

No longer delivering PoE

Device power budget exceeded

Minor

Not enough power remaining in the budget

Stack member power unit failure

Major

A stack member can no longer deliver PoE

Stack members power unit failure

Major

Multiple stack members can no longer deliver POE

Stack member power budget exceeded

Minor

Not enough power remaining in the budget for a stack member

Stack members power budget exceeded

Minor

Not enough power remaining in the budget for stack members

Stack member not updated

Minor

A stack member failed the software update after repeated attempts.

Check that the device is connected. Check the configuration of network services (such as DHCP, DNS, and firewalls). Make sure the instant-on.hpe.com domain is allow-listed. Restart the device or Internet gateway. Review the software update status and try to reinstall the software version(click View software update/ Retry software update to open the Software page).

Stack members not updated

Minor

Multiple stack members failed the software update.

Check that the device is connected. Check the configuration of network services (such as DHCP, DNS, and firewalls). Make sure the instant-on.hpe.com domain is allow-listed. Restart the device or Internet gateway. Review the software update status and try to reinstall the software version(click View software update/ Retry software update to open the Software page).

Watchlisted client offline

Minor

A watchlisted client went offline

Uplink type changed

Informational

The device uplink has changed from a wired connection to an over-the-air connection

Domain offline

Major

All tunnels are down (main site)

Connection to domain offline

Minor

Tunnel down (connected site).

WAN offline

Minor

WAN connection is offline.

Incompatible device management VLAN

Major

The management VLAN provisioned on the device differs from the one configured on the site. The device is Suspended until the VLANs match.

Alert Triggered When Instant On AP25 Access Point is Underpowered

The Instant On AP25 access points require a minimum power 802.3at (Class 4) to function properly. In an event where the device is underpowered, an alert is displayed on the Access Point Details page. The Radios section of the page also displays a warning after disabling the radio settings of the AP. The LED on the device continues to flash rapid amber until sufficient power supply is provided and turns to solid green.

When the underpowered AP25 access points is a mesh point, no alert or warning will be displayed on the Instant On application.